Review





Similar Products

86
Danaher Inc element cardiac coil
Element Cardiac Coil, supplied by Danaher Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/nct05237505-5-17-11?v=Danaher+Inc
Average 86 stars, based on 1 article reviews
element cardiac coil - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Asahi Intecc Co Ltd tapered coil guidewire
Intra-procedural fluoroscopic images demonstrating the recanalization technique. (A) A <t>guidewire</t> is advanced from the ureter, successfully puncturing into the balloon-distended renal pelvis (arrowhead). (B) A snare catheter (arrowhead) introduced via the nephrostomy sheath captures the guidewire in the renal pelvis. (C) The guidewire is externalized through the flank, establishing through-and-through access. (D) Final image showing the double-J stent correctly positioned across the new tract, with a pigtail catheter in the renal pelvis.
Tapered Coil Guidewire, supplied by Asahi Intecc Co Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/pmc13254955-60-20-27?v=Asahi+Intecc+Co+Ltd
Average 86 stars, based on 1 article reviews
tapered coil guidewire - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Stratech Scientific Ltd coil
Intra-procedural fluoroscopic images demonstrating the recanalization technique. (A) A <t>guidewire</t> is advanced from the ureter, successfully puncturing into the balloon-distended renal pelvis (arrowhead). (B) A snare catheter (arrowhead) introduced via the nephrostomy sheath captures the guidewire in the renal pelvis. (C) The guidewire is externalized through the flank, establishing through-and-through access. (D) Final image showing the double-J stent correctly positioned across the new tract, with a pigtail catheter in the renal pelvis.
Coil, supplied by Stratech Scientific Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/pmc13138298-97-9-16?v=Stratech+Scientific+Ltd
Average 86 stars, based on 1 article reviews
coil - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Boston Scientific Corporation detachable coils
Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of <t>detachable</t> coils followed by additional pushable coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.
Detachable Coils, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/pmc13196357-35-0-6?v=Boston+Scientific+Corporation
Average 86 stars, based on 1 article reviews
detachable coils - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Piolax Medical Devices Inc additional pushable coils
Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional <t>pushable</t> coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.
Additional Pushable Coils, supplied by Piolax Medical Devices Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/pmc13196357-35-21-26?v=Piolax+Medical+Devices+Inc
Average 86 stars, based on 1 article reviews
additional pushable coils - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Boston Scientific Corporation coils
Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional <t>pushable</t> coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.
Coils, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/pmc13273459-40-28-33?v=Boston+Scientific+Corporation
Average 86 stars, based on 1 article reviews
coils - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Philips Healthcare in house 10 inch circle shaped mouse receiver coil array
Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional <t>pushable</t> coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.
In House 10 Inch Circle Shaped Mouse Receiver Coil Array, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/pmc08506607-339-12-21?v=Philips+Healthcare
Average 86 stars, based on 1 article reviews
in house 10 inch circle shaped mouse receiver coil array - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Philips Healthcare channel phased array head neck coil
Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional <t>pushable</t> coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.
Channel Phased Array Head Neck Coil, supplied by Philips Healthcare, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/pm42320610-61-31-25?v=Philips+Healthcare
Average 86 stars, based on 1 article reviews
channel phased array head neck coil - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Siemens Healthineers 32 channel head rf coil
Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional <t>pushable</t> coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.
32 Channel Head Rf Coil, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/pm42316513-109-15-19?v=Siemens+Healthineers
Average 86 stars, based on 1 article reviews
32 channel head rf coil - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

86
Siemens Healthineers 32 channel head coil
Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional <t>pushable</t> coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.
32 Channel Head Coil, supplied by Siemens Healthineers, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/coils/pm42313423-48-23-26?v=Siemens+Healthineers
Average 86 stars, based on 1 article reviews
32 channel head coil - by Bioz Stars, 2026-07
86/100 stars
  Buy from Supplier

Image Search Results


Intra-procedural fluoroscopic images demonstrating the recanalization technique. (A) A guidewire is advanced from the ureter, successfully puncturing into the balloon-distended renal pelvis (arrowhead). (B) A snare catheter (arrowhead) introduced via the nephrostomy sheath captures the guidewire in the renal pelvis. (C) The guidewire is externalized through the flank, establishing through-and-through access. (D) Final image showing the double-J stent correctly positioned across the new tract, with a pigtail catheter in the renal pelvis.

Journal: Radiology Case Reports

Article Title: Percutaneous antegrade-retrograde recanalization (rendezvous technique) of a complete ureteropelvic junction disruption after robotic-assisted partial nephrectomy: A case report

doi: 10.1016/j.radcr.2026.05.030

Figure Lengend Snippet: Intra-procedural fluoroscopic images demonstrating the recanalization technique. (A) A guidewire is advanced from the ureter, successfully puncturing into the balloon-distended renal pelvis (arrowhead). (B) A snare catheter (arrowhead) introduced via the nephrostomy sheath captures the guidewire in the renal pelvis. (C) The guidewire is externalized through the flank, establishing through-and-through access. (D) Final image showing the double-J stent correctly positioned across the new tract, with a pigtail catheter in the renal pelvis.

Article Snippet: To obtain more robust backup support, the ureteral access sheath was manually curved, and the tail end of a stiffer tapered-coil guidewire (Astato XS 9-40, 200 cm, Asahi Intecc) was advanced toward the snare under lateral fluoroscopic projection.

Techniques:

Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional pushable coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.

Journal: Radiology Case Reports

Article Title: Balloon-assisted coil embolization for high-flow renal arteriovenous fistula with inferior vena cava dilatation: A report of two cases

doi: 10.1016/j.radcr.2026.04.046

Figure Lengend Snippet: Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional pushable coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.

Article Snippet: Detachable coils (Interlock and EMBOLD coils; Boston Scientific Corporation, Marlborough, MA, USA) were first deployed to create a stable frame, and additional pushable coils (C-STOPPER coils; Piolax Medical Devices, Yokohama, Japan; AZUR D-18 coils; Terumo Corporation, Tokyo, Japan; GALAXY G3 and DELTAFILL 18 coils; Cerenovus, Irvine, CA, USA) were then packed within this framework from the venous side toward the arterial side under balloon occlusion, with the aim of increasing the coil filling rate and achieving dense packing.

Techniques:

Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional pushable coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.

Journal: Radiology Case Reports

Article Title: Balloon-assisted coil embolization for high-flow renal arteriovenous fistula with inferior vena cava dilatation: A report of two cases

doi: 10.1016/j.radcr.2026.04.046

Figure Lengend Snippet: Case 1: Renal angiography and balloon-assisted coil embolization of a right RAVF (A) Baseline right renal angiogram demonstrating a large high-flow RAVF arising from a focally dilated segment of the right renal artery and draining into markedly dilated venous channels, with poor opacification of the renal parenchyma. (B) Angiogram obtained with the balloon catheter inflated in the right renal artery near the shunt showing disappearance of the arteriovenous shunt and improved cortical enhancement via preserved proximal branches, indicating an optimal level for embolization. (C) Final angiogram after balloon-assisted deployment of detachable coils followed by additional pushable coils within the shunt and proximal draining vein, showing complete occlusion of the fistula with preserved antegrade flow into the normal segmental branches. RAVF, renal arteriovenous fistula.

Article Snippet: Detachable coils (Interlock and EMBOLD coils; Boston Scientific Corporation, Marlborough, MA, USA) were first deployed to create a stable frame, and additional pushable coils (C-STOPPER coils; Piolax Medical Devices, Yokohama, Japan; AZUR D-18 coils; Terumo Corporation, Tokyo, Japan; GALAXY G3 and DELTAFILL 18 coils; Cerenovus, Irvine, CA, USA) were then packed within this framework from the venous side toward the arterial side under balloon occlusion, with the aim of increasing the coil filling rate and achieving dense packing.

Techniques: